professional cleaning services

call or email us for your free professional cleaning estimate

FIRE RESOURCE CENTER

ROC # 256522
2346 E. University Drive, Suite # 180
Phoenix, AZ 85034

PH: 602-386-3024
FAX: 602-454-6791
FRC can arrange for one of our professional service team members to visit your property for a comprehensive fire safety inspection. All team members are CSA and/or NICET certified. FRC is ready to provide service on a service agreement basis. However basic or complex your system, our team will provide you with the finest in customer service for your all your Fire Protection needs, including: Hood Systems, Sprinkler Systems, Extinguishers, Hydrants, and Fire Pumps. From inspections to repairs, our trained staff can provide you with competitive quote to fulfill your needs.

COMPLETE FIRE PROTECTION: SALES AND SERVICE

SPECIALIZING IN:

Fire Sprinkler Systems

Inspections and Repairs

Fire Pumps

Weekly Inspections and Repairs Preventative Maintenance on all types of Systems
Our fire protection professionals specialize in providing swift, efficient service of your system. Each system is carefully tested. Our attention to detail, coupled with an acute adherence to fire protection standards and customer service allow us to achieve the highest quality effectiveness.

Fire Extinguishers

Inspections and Repairs
Recharge and Maintenance on all types of Portables

Kitchen Hood System

Inspections and Repairs
testing semi-annually per NFPA 17
A written report by our service technician points out changes that may need to be made, including helpful suggestions. Our service personnel possess up-to-date knowledge of fire codes, many insurance requirements, and the various types of fire protection systems. With our fire sprinkler inspection and other services that we provide you can rest assured that your systems are prepared to offer life safety for the building's occupants as well as property protection.

Exit Lights

Emergency Lights

Batteries


NATIONAL FIRE CODES:

 Fire Extinguishers - NFPA-10

4-4.1 Frequency. Extinguishers shall be subject to maintenance not more than one year apart or when specifically indicated by an inspection. Maintenance procedures shall be performed in accordance with 4-4.2.

4-4.1.3 Every six years, stored pressure extinguishers that require a 12-year hydrostatic test shall be emptied and subjected to the appropriate maintenance procedures. When the applicable maintenance procedures are performed during periodic recharging or hydrostatic testing, the six-year requirement shall begin from that date.

 Restaurant/Industrial Fire Suppression Systems - NFPA 17, 17A, 96

3-3.1 At least semi-annually, maintenance shall be conducted in accordance with the manufacture's listed installation and maintenance manual

2-11.3 Fixed temperature sensing elements of the fusible metal alloy type shall be replaced at least annually or more frequently if necessary to assure proper operation of the system.

 Fire Sprinkler Systems - NFPA 25

9-2.6 Main Drain Test. A main drain test shall be conducted quarterly at each system riser to determine if there has been a change in the condition of the water supply piping and control valves.

9-2.7 Waterflow Alarm. All waterflow alarms shall be tested quarterly in accordance with the manufacture's instructions.

2-3.3.1 Testing the waterflow alarms on wet pipe systems shall be accomplished by opening the inspector's test connection.

 Fire Alarm Systems - NFPA 72

7-3.2 Testing. Testing shall be performed in accordance with the schedules in this chapter or more frequently where required by the authority having juristiction. Where automatic testing is performed at least weekly by a remotely monitored fire alarm control unit specifically listed for the application, the manual testing frequency shall be permitted to be extended to annually.

 Emergency & Exit Signs & Lighting - NFPA 101

5-10.1.2 Exits shall be marked by an approved sign readily visible from any direction of exit access.

5-9.2.1 Emergency illumination shall be provided for a period of 90 minutes in the event of failure of normal lighting.

 Hand Held Fire Hose - NFPA 1962

2-3.3 In-service hose shall be unracked, unreeled, or unrolled and physically inspected as specified in Section 2-5 at least annually. Hose shall be reracked, rereeled, or rerolled so that any folds do not occur at the same position on the hose.